Cell counting techniques

Examining CSF with the Hemacytometer

Specimens that are clear may be counted undiluted as long as there is no overlapping of the cells. Examining an undiluted CSF involves the following steps:

  • Mix the CSF manually 6 - 10 times or place it in a mechanical mixer for 5 minutes.
  • Using a Pasteur pipet or Dispo® pipet, fill both sides of the hemacytometer and allow the cells to settle for 5 minutes. To prevent the fluid in the chamber from evaporating, place it in a Petri dish containing moist filter paper. A disposable chamber similar to a hemacytometer is preferred, if one is available.
  • Focus on low power (10x) and scan for the presence of cells. If cells are located, switch to high power (40x) to determine whether the cells are leukocytes or erythrocytes. Erythrocytes will be smooth refractile discs or spheres. Some red cells may appear crenated. Keep in mind that some red cells may be folded or in a vertical position rather than flat. In this situation only a small portion of the cell will be visible.

Learn more about laboratory continuing education for individuals and lab safety and compliance courses for the whole lab.

Cerebrospinal Fluid course details »

Learn more about medical technologist continuing education for MTs, MLTs, and other lab personnel »

Get information on laboratory compliance training for clinical and medical laboratories »