These are the MediaLab courses that cover Microbial and links to relevant pages within the course.

Learn more about laboratory continuing education for medical technologists to earn CE credit for AMT, ASCP, NCA, and state license renewal and recertification. Or get information about laboratory safety and compliance courses that deliver cost-effective OSHA safety training and continuing education to your laboratory's employees.

Laboratories Individuals

Chemical Screening of Urine by Reagent Strip
False Positive Results

A false positive result for blood on the reagent strip can occur when oxidizing contaminants, such as hypochlorite (bleach), remain in collection bottles after cleaning. Contamination of the urine with provodine-iodine, a strong oxidizing agent, used in surgical procedures can result in a false positive reaction. Microbial peroxide found in association with urinary tract infections may also cause false-positive results. CapotenĀ® (Captopril) can cause decreased reactivity. The muscle tissue form of hemoglobin, myoglobin is a well-known cause of false-positive reactions on the blood portion of the reagent strip. When tissue hemoglobin is present, the urine specimen has a clear red appearance. Patients suffering from muscle-wasting disorders or muscular destruction due to trauma, prolonged coma, or convulsions or individuals engaging in extensive exertion may have myoglobin in their urine. Specific tests for myoglobin, such as immunodiffusion techniques or protein electrophoresis, are needed to confirm the presence of this substance in a urine specimen. Levels of ascorbic acid normally found in urine do not interfere with this test.

View Page
Which of the following substances cause a false positive result for blood on the urine reagent strip? (Choose ALL of the correct answers)View Page
Which of the following substances may cause a false negative result for blood on the urine reagent strip? (Choose ALL of the correct answers)View Page

CLIA Microbiology / Serology Review
MIC is an acronym for:View Page

Current Topics in Clinical Microbiology
Review 3

Ladhani S. Joannou CL. Lochrie DP. Evans RW. Poston SM.: Clinical, microbial, and biochemical aspects of the exfoliative toxins causing staphylococcal scalded-skin syndrome. Clinical Microbiology Reviews. 12:224-242, 1999The exfoliative (epidermolytic) toxins of Staphylococcus aureus are the causative agents of the staphylococcal scalded-skin syndrome (SSSS), a blistering skin disorder that predominantly affects children. Clinical features of SSSS vary along a spectrum, ranging from a few localized blisters to generalized exfoliation covering almost the entire body.The toxins act specifically at the zona granulosa of the epidermis to produce the characteristic exfoliation, although the mechanism by which this is achieved is still poorly understood.Despite the availability of antibiotics, SSSS carries a significant mortality rate, particularly among neonates with secondary complications of epidermal loss and among adults with underlying diseases.

View Page

Electrophoresis
Buffers

To prevent microbial growth and contamination, buffers must be refrigerated when not in use. Using a buffer at refrigerator temperature also improves band resolution and lessens evaporation during electrophoresis. It is recommended that an electrophoresis using a small volume of buffer use a fresh buffer for each run. After a large volume buffer electrophoresis, the buffer can be reused if the buffer from each reservoir is combined, mixed well, and refrigerated.

View Page