Drug-metabolizing Information and Courses from MediaLab, Inc.
These are the MediaLab courses that cover Drug-metabolizing and links to relevant pages within the course.
Learn more about laboratory continuing education for medical technologists to earn CE credit for AMT, ASCP, NCA, and state license renewal and recertification. Or get information about laboratory safety and compliance courses that deliver cost-effective OSHA safety training and continuing education to your laboratory's employees.
| Unexpected Concentrations TDM provides a quantitative measure of the circulating concentration of a drug. The physician determines if the dosage of the drug needs to be adjusted based on this information.If a drug concentration is determined to be outside the therapeutic range, it may be for one of the reasons listed in the table below. Reason Discussion Noncompliance Patients may (intentionally or unintentionally) not take the drug. TDM can thus help monitor compliance. Dosing errors The dose may have been erroneous or inappropriate given the patient's condition. Malabsorption The TDM result will reveal if the drug cannot be absorbed well through the gut and an alternative route of administration will be needed. Drug interactions Many drugs interfere with the absorption or metabolism of other drugs. These interactions will be revealed by TDM. Kidney or liver disease Any pathology that affects elimination will cause an elevation in a drug level that will be unmasked by TDM. Altered protein binding Changes in serum proteins can lead to big changes in the amount of free drug in serum. Variations in the genetics of drug-metabolizing enzymes can also affect drug concentrations in the body. This is the field of pharmacogenomics that will be discussed later in the course. | View Page |
| Clinical Utility The ultimate goal in measuring CYP450 function or identifying polymorphisms is to predict effective therapeutic doses and responses in patients.Polymorphisms are identified using molecular techniques (allele-specific PCR, restriction digests, sequencing, hybridization assays, bead-based systems, microarrays, pyrosequencing, et al).Although most clinical labs do not offer PGx testing, reference labs are beginning to market these tests. For example, one reference laboratory in the Midwest that offers CYP2D6 profiling measures about one dozen of the most common and significant mutation sites on this enzyme. This allows for detection of approximately 98% of the known CYP2D6 polymorphisms. The laboratory then generates a report which will advise the physician on the patient's drug-metabolizing status.Estimates show that 6-10% of the general population have a complete deficiency of CYP2D6, with the prevalence of mutations varying from <1% to as much as 21% within a given population. | View Page |