Subscriber Login Students | Administrators
Online compliance and continuing education courses for clinical laboratories

Autocontrol Information and Courses from MediaLab, Inc.

These are the MediaLab courses that cover Autocontrol and links to relevant pages within the course.

Learn more about laboratory continuing education for medical technologists to earn CE credit for AMT, ASCP, NCA, and state license renewal and recertification. Or get information about laboratory safety and compliance courses that deliver cost-effective OSHA safety training and continuing education to your laboratory's employees.

Laboratories Individuals

CLIA Blood Banking Review
A patient's serum reacts with all reagent red cell samples. The autocontrol is negative. An alloantibody to a high incidence antigen is suspected. Which of the following would be most likely to be a compatible donor:View Page

The Disappearing Antibody: A Case Study
Antibody identification checklist

To improve the quality of conclusions when identifying antibodies, a checklist is a simple quality control tool to increase transfusion safety. If a specific antibody pattern cannot be identified with acceptable confidence, or if significant serologic or non-serologic data are inconsistent and cannot be rationalized, further testing will be required.Before concluding that the investigation is complete, unless not applicable, mentally reply to each question in the checklist. If any answer is no, has it been resolved? Antibody Identification Checklist Yes/No/NA 1. For a single antibody, does the reaction pattern fit only one antibody specificity? 2. Is antibody specificity consistent with the results of the initial antibody screen? 3. Are reaction phases consistent with antibody specificity? 4. If multiple antibodies are present, can all reactions be explained by the antibody combination? 5. If the autocontrol is negative, are patient red cells negative for the corresponding antigen(s)? 6. Have additional possible antibodies been excluded by selected red cells? 7. Can all variable reaction strengths be explained? 8. If tested, are antigen-negative donor cells compatible by antiglobulin crossmatch? 9. If there are data that do not fit antibody specificity or if there are results that are improbable, are they explainable? 10. Have all results and conclusions been systematically evaluated for consistency?

View Page
DAT change of status

Notice that the patient's DAT is now negative (IAT autocontrol in the panel done 2-weeks post-transfusion is negative). Cell Rh Rhesus Kell Duffy Kidd MNSs P Lewis Lu Results Cell C D E c e Cw K k Kpa Fya Fyb Jka Jkb M N S s P1 Lea Leb Lua Gel IAT* 1 rr 0 0 0 + + 0 0 + 0 + 0 + 0 0 + + + +S + 0 0 1+ 1 2 rr 0 0 0 + + 0 0 + 0 + 0 + + 0 + + + +S + 0 0 w+ 2 3 rr 0 0 0 + + 0 0 + 0 + + 0 + 0 + + 0 + 0 + 0 0 3 4 r"r 0 0 + + + 0 0 + 0 + + 0 + 0 + 0 + + + 0 0 0 4 5 R2R2 0 + + + 0 0 + 0 0 + + + + + 0 + 0 + 0 + 0 w+ 5 6

View Page


MediaLab, Inc.

http://www.MediaLabInc.net    |    (877) 776-8460 (tollfree)    |    sales@medialabinc.net